System: 10 - Safety Of Navigation Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: In Addition, Test And Inspections Shall Be Conducted To Determine The Service Ability Of All Protective Enclosures And Devices Fitted To The Location. Psco Observed A Fault Reading “channel 11” On The Vdr. A Restriction Was Issued To Provide A Class Report Attesting To A Fully Operational Vdr With No Alarms. 74solas2020 V/18.8, 17ac Due Date: 7/13/2023 12:00:00 Am Deficiency Resolved? Yes Resolved Date: 7/14/2023 12:00:00 Am Resolution Description: Psc Nola Received A Class Report From Lloyd's Register Satisfying The Requirement. System: 03 - Water/weathertight Conditions Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: All Hatchways In Position 1 And 2 Shall Be Fitted With Hatch Material, Except As Provided In Reg 14(2). Such Covers Shall Be Weathertight And Fitted With Gaskets And Clamping Devices. Psco Observed Multiple Ventilation Hatches Dogs Missing On The Watertight Hatches On Deck And Cargo Ventilation Hatches. A Requirement Was Issued To Provide A Class Report Attesting To The Replacement Of The Missing Dogs On All Cargo Ventilation Covers And Watertight Hatches On Deck Prior To Departure. Icll 66/88 Annex I/16.1, 17ac Due Date: 7/13/2023 12:00:00 Am Deficiency Resolved? Yes Resolved Date: 7/14/2023 12:00:00 Am Resolution Description: Psc Nola Received A Class Report From Lloyd's Register Satisfying The Requirement. System: 07 - Fire Safety Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: Fire Protection System And Fire Fighting Systems And Appliances Shall Be Maintained Ready For Use. Psco Oberved (1) Zone 6, Cable/short Circut Fault On The Fire Dection System On The Bridge. (2) Psco Observed No Power To The Engine Room Alarm Panel In The Engine Control Room. (3) Psco Observed No Power To The Co2 Alarm Relay Box In The Co2 Room. 74 Solas 2020, Ii-2/14.1, 60ac Due Date: 7/13/2023 12:00:00 Am Deficiency Resolved? Yes Resolved Date: 7/14/2023 12:00:00 Am Resolution Description: Psc Nola Received A Class Report From Lloyd's Register Satisfying The Requirement. System: 14 - Pollution Prevention Sub-system: 145 - Marpol Annex V Cause: Description Of Deficiency: The Gmp Shall Also Designate The Person Or Persons In Charge Of Carrying Out The Plan. C/o Stated He Is In Charge Of The Plan But Could Not Show Where It Was Documented In Gmp. Marpol Annex V 10.2, 40ac Due Date: 9/30/2023 12:00:00 Am Deficiency Resolved? Yes Resolved Date: 7/14/2023 12:00:00 Am Resolution Description: Psc Nola Received A Class Report From Lloyd's Register Satisfying The Requirement. System: 14 - Pollution Prevention Sub-system: 145 - Marpol Annex V Cause: Description Of Deficiency: The Gmp Shall Provide Written Procedures For Minimizing, Collecting, Storing, Processing, And Disposing Of Garbage, Including The Use Of The Equipment Onboard. Vessel Gmp Does Not List The Processing Equipment Or Address The Use Of Onboard Equipment. Marpol Annex V 10.2, 40ac Due Date: 9/30/2023 12:00:00 Am Deficiency Resolved? Yes Resolved Date: 7/14/2023 12:00:00 Am Resolution Description: Psc Nola Received A Class Report From Lloyd's Register Satisfying The Requirement. System: 02 - Structural Conditions Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: The Master, Owner, Operator, Agent, Or Person In Charge Of A Vessel Equipped With Ballast Tanks That Operates In The Waters Of The United States Must Employ One Of The Authorized Ballast Water Management Methods Listed In 33 Cfr 151.2025(a). Vessel’s Ballast Water Management System Is Inoperable. Vessel Has Been Granted An Extraordinary Circumstance To Employ The Ballast Water Management Method Listed In 33 Cfr 151.2025(a)(3) To Conduct Cargo Operations While In The Sector New Orleans Cotp Zone. In Accordance With 33 Cfr 151.2040(b)(3), The Vessel Must Discharge Only That Amount Of Ballast Water Operationally Necessary To Ensure The Safety And Stability Of The Vessel For Cargo Operations. Due Date: 7/22/2023 12:00:00 Am Deficiency Resolved? Yes Resolved Date: 7/14/2023 12:00:00 Am Resolution Description: Psc Nola Received A Class Report From Lloyd's Register Satisfying The Requirement. System: 13 - Propulsion And Auxiliary Machinery Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: The Purpose Of This Regulation Is To Prevent The Ignition Of Combustible Materials Or Flammable Liquids. For This Purpose, The Following Functional Requirements Shall Be Met, 3. The Limitability Of Combustible Materials Shall Be Restricted. Psco Observed Excessive Oil And Oily Rags In The Bilge Beneath #3 Generator. A Requirement Was Issued To Provide A Class Report Attesting To The Removeable Of The Oil/oily Rags Under The Generator Prior To Departure. 74solas 2020, Ii-2/4.1.3, 17ac Due Date: 7/13/2023 12:00:00 Am Deficiency Resolved? Yes Resolved Date: 7/14/2023 12:00:00 Am Resolution Description: Psc Nola Received A Class Report From Lloyd's Register Satisfying The Requirement.
Inspection date
2023-02-17
Technical ism manager
-
Inspection authority
CHINA
Address
Suite 1405, 477 Madison Avenue, New York
united States Of America 10022-5837
Inspection port
Nanjing
Phone
+1 2127852500
Inspection type
Initial
Email
-
Detention
FALSE
Website
http://www.eagleships.com/
Ship deficiencies
2
Deficiency description
Emergency Systems (fire Drills) ; Emergency Systems (emergency Source Of Power - Emergency Generator)
Inspection date
2022-07-12
Technical ism manager
-
Inspection authority
SPAIN
Address
National Road Athens-lamia, Kifisia, Athens, United States