Home>Vessels>DETROIT JET
Vessel

DETROIT JET

MOROCCO
MA flag

Country

MA flag
MOROCCO

Year

2000

Status

Active

Vessel details

Vessel MMSI number

242911000

Vessel IMO number

9216169

Vessel type

HIGH SPEED CRAFT

Vessel subtype

HIGH SPEED CRAFT

Gross tonnage

2869

Deadweight

190

Twenty-foot Equivalent Unit (TEU)

Not Available

Vessel length in meters

72

Vessel breadth in meters

17.5

Ship liquid gas capacity

-

Call sign

CNA4468

Current vessel live info

Last position info time - - -

Current draught of the vessel

-

Maximum draught of the vessel

-

Current reported speed of the vessel

-

Current vessel speed in knots

-

Maximum speed of the vessel

-

Vessel activity status

-

Current vessel longitude

-

Current vessel latitude

-

Current vessel course in degrees

-

Current vessel heading in degrees

-

Port name of the next planned stop

-

Estimated time of arrival in UTC

-

Owner company details

This vessel's owner company details are not available.

Casualities details

Ship casualties, including types of incidents, specific dates, and additional narrative details.
This vessel has never experienced any casualties.

Ship inspections

Inspection date
2023-08-04
Technical ism manager
-
Inspection authority
SPAIN
Address
Rue Farabi, Tangier, Morocco
Inspection port
Tarifa
Phone
-
Inspection type
Follow-up
Email
-
Detention
FALSE
Website
-
Ship deficiencies
12
Deficiency description
11104, Rescue Boats, Life Saving Appliances, 1047, Not Ready For Use, 10118, Speed And Distance Indicator, Safety Of Navigation, 1082, Inoperative, 99102, Other (solas Operational), Other, 1238, Other, 10101, Pilot Ladders And Hoist/pilot Transfer Arrangements, Safety Of Navigation, 1000, Missing, 11105, Rescue Boat Inventory, Life Saving Appliances, 1031, Incomplete, 08101, General Alarm, Alarms, 1100, Malfunctioning, 08199, Other (alarms), Alarms, 1238, Other, 10110, Signalling Lamp, Safety Of Navigation, 1082, Inoperative, 10116, Nautical Publications, Safety Of Navigation, 1004, Expired, 07109, Fixed Fire Extinguishing Installation, Fire Safety, 1011, Not As Required, 15150, Ism, Ism, 1011, Not As Required, 10199, Other (navigation), Safety Of Navigation, 1238, Other
Inspection date
2022-09-02
Technical ism manager
-
Inspection authority
SPAIN
Address
Rue Farabi, Tangier, Morocco
Inspection port
Tarifa
Phone
-
Inspection type
Detailed
Email
-
Detention
FALSE
Website
-
Ship deficiencies
5
Deficiency description
10114, Voyage Data Recorder (vdr) / Simplified Voyage Data Recorder (s-vdr), Safety Of Navigation, 1011, Not As Required, 03112, Scuppers, Inlets And Discharges, Water/weathertight Conditions, 1011, Not As Required, 07115, Fire-dampers, Fire Safety, 1011, Not As Required, 03105, Covers (hatchway-, Portable-, Tarpaulins, Etc.), Water/weathertight Conditions, 1086, Not Properly Maintained, 07106, Fire Detection And Alarm System, Fire Safety, 1011, Not As Required,
Inspection date
2022-08-01
Technical ism manager
-
Inspection authority
SPAIN
Address
Rue Farabi, Tangier, Morocco
Inspection port
Cadiz
Phone
-
Inspection type
Follow-up
Email
-
Detention
TRUE
Website
-
Ship deficiencies
21
Deficiency description
04101, Public Address System, Emergency Systems, 1082, Inoperative, 13101, Propulsion Main Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required, 10116, Nautical Publications, Safety Of Navigation, 1000, Missing, 11113, Launching Arrangements For Rescue Boats, Life Saving Appliances, 1086, Not Properly Maintained, 04104, Low Level Lighting In Corridors, Emergency Systems, 1082, Inoperative, 13101, Propulsion Main Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required, 07105, Fire Doors/openings In Fire-resisting Divisions, Fire Safety, 1011, Not As Required, 13102, Auxiliary Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required, 18327, Ventilation (working Spaces), Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1082, Inoperative, 01117, International Oil Pollution Prevention (iopp), Certificate & Documentation - Ship Certificates, 1003, Not Properly Filled, 04114, Emergency Source Of Power - Emergency Generator, Emergency Systems, 1011, Not As Required, 01315, Oil Record Book, Certificate & Documentation - Documents, 1003, Not Properly Filled, 07109, Fixed Fire Extinguishing Installation, Fire Safety, 1011, Not As Required, 07106, Fire Detection And Alarm System, Fire Safety, 1011, Not As Required, 04103, Emergency, Lighting,batteries And Switches, Emergency Systems, 1086, Not Properly Maintained, 08107, Machinery Controls Alarm, Alarms, 1100, Malfunctioning, 07115, Fire-dampers, Fire Safety, 1082, Inoperative, 18409, Dangerous Areas, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe, 13102, Auxiliary Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required, 13102, Auxiliary Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required, 15150, Ism, Ism, 1011, Not As Required
Inspection date
2022-06-27
Technical ism manager
-
Inspection authority
UNITED KINGDOM
Address
Rue Farabi, Tangier, Morocco
Inspection port
Gibraltar
Phone
-
Inspection type
Follow-up
Email
-
Detention
FALSE
Website
-
Ship deficiencies
5
Deficiency description
13199, Other (machinery), Propulsion And Auxiliary Machinery, 1238, Other, 10112, Electronic Charts (ecdis), Safety Of Navigation, 1179, Not Updated, 05199, Other (radiocommunication), Radio Communications, 1238, Other, 10116, Nautical Publications, Safety Of Navigation, 1179, Not Updated, 04102, Emergency Fire Pump And Its Pipes, Emergency Systems, 1110, Insufficient Pressure,

Detroit Jet port map

© 2024 boatdb.
|