Home>Vessels>HAMBURG WAY
Vessel

HAMBURG WAY

PHILIPPINES
PH flag

Country

PH flag
PHILIPPINES

Year

2016

Status

Active

Vessel details

Vessel MMSI number

548940000

Vessel IMO number

9743227

Vessel type

CARGO

Vessel subtype

BULK CARRIER

Gross tonnage

24872

Deadweight

39376

Twenty-foot Equivalent Unit (TEU)

Not Available

Vessel length in meters

179.9

Vessel breadth in meters

30

Ship liquid gas capacity

-

Call sign

DUIF

Current vessel live info

Last position info time - - -

Current draught of the vessel

-

Maximum draught of the vessel

-

Current reported speed of the vessel

-

Current vessel speed in knots

-

Maximum speed of the vessel

-

Vessel activity status

-

Current vessel longitude

-

Current vessel latitude

-

Current vessel course in degrees

-

Current vessel heading in degrees

-

Port name of the next planned stop

-

Estimated time of arrival in UTC

-

Owner company details

Company name
Nisshin Shipping
Company type
OWNER
Country
JPN flagJapan
Address
119th Floor, Nihonbashi 1-chome Building, 4-1, Nihonbashi 1-chome, Chuo-ku, Tokyo, 103-0027, Japan
Parent company
Not Available
Parent company IMO
Not Available
Phone number
+81 3 5204 1211
Email
ship@bigthree.co.jp
Website
Not Available
LinkedIn
Not Available

Casualities details

Ship casualties, including types of incidents, specific dates, and additional narrative details.
This vessel has never experienced any casualties.

Ship inspections

Inspection date
2023-06-09
Technical ism manager
-
Inspection authority
POLAND
Address
Rcm Building, 1418, San Marcelino Street, Ermita, Manila, Philippines
Inspection port
Gdynia
Phone
+63 23381633
Inspection type
Detailed
Email
vsmi-mla@vsmi.com.ph
Detention
FALSE
Website
-
Ship deficiencies
6
Deficiency description
Oil Record Book Entries Missing ; Records Of Seafarers' Daily Hours Of Work Or Rest False ; Retention Of Oil On Board Not As Required ; Fire Prevention Structural Integrity Not As Required ; Ism Not As Required ; Emergency Source Of Power - Emergency Generator Not As Required
Inspection date
2023-03-13
Technical ism manager
-
Inspection authority
AUSTRALIA
Address
Rcm Building, 1418, San Marcelino Street, Ermita, Manila, Philippines
Inspection port
Townsville, Qld
Phone
+63 23381633
Inspection type
Follow-up
Email
vsmi-mla@vsmi.com.ph
Detention
FALSE
Website
-
Ship deficiencies
1
Deficiency description
Emergency Systems (emergency Source Of Power - Emergency Generator)
Inspection date
2023-03-10
Technical ism manager
-
Inspection authority
AUSTRALIA
Address
Rcm Building, 1418, San Marcelino Street, Ermita, Manila, Philippines
Inspection port
Townsville, Qld
Phone
+63 23381633
Inspection type
Initial
Email
vsmi-mla@vsmi.com.ph
Detention
FALSE
Website
-
Ship deficiencies
5
Deficiency description
1 04114 Emergency Systems (emergency Source Of Power - Emergency Generator) No 2 04116 Emergency Systems (means Of Communication Between Safety Centre And Other Control Stations) No 3 07109 Fire Safety (fixed Fire Extinguishing Installation) No 4 07110 Fire Safety (fire Fighting Equipment And Appliances) No 5 18499 Labour Conditions-health Protection, Medical Care,social Security (other (health Protection, Medical Care...)) No
Inspection date
2023-01-02
Technical ism manager
-
Inspection authority
PERU
Address
Rcm Building, 1418, San Marcelino Street, Ermita, Manila, Philippines
Inspection port
Salaverry
Phone
+63 23381633
Inspection type
Initial
Email
vsmi-mla@vsmi.com.ph
Detention
FALSE
Website
-
Ship deficiencies
-
Deficiency description
-
Inspection date
2022-04-29
Technical ism manager
-
Inspection authority
SPAIN
Address
Sodragatan 13, Ax-22100 , Mariehamn, Philippines
Inspection port
Algeciras
Phone
-
Inspection type
Detailed
Email
-
Detention
FALSE
Website
-
Ship deficiencies
4
Deficiency description
04112, Shipboard Marine Pollution Emergency Operations, Emergency Systems, 1011, Not As Required, 11104, Rescue Boats, Life Saving Appliances, 1047, Not Ready For Use, 04101, Public Address System, Emergency Systems, 1082, Inoperative, 04103, Emergency, L
Inspection date
2022-04-18
Technical ism manager
-
Inspection authority
TURKEY
Address
-
Inspection port
Canakkale
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
3
Deficiency description
Safety Of Navigation, 10133 - Bridge Operation, Lack Of Familiarity Certificate & Documentation - Documents, 01308 - Records Of Seafarers' Daily Hours Of Work Or Rest, Incorrect Entries Certificate & Documentation - Documents, 01310 - Signs, Indications,
Inspection date
2021-11-17
Technical ism manager
-
Inspection authority
GERMANY
Address
Harburger Strasse 47-51, 21614 , Buxtehude, Philippines
Inspection port
Brake
Phone
-
Inspection type
Detailed
Email
-
Detention
FALSE
Website
-
Ship deficiencies
20
Deficiency description
02103, Stability/strength/loading Information And Instruments, Structural Conditions, 1011, Not As Required, 01308, Records Of Seafarers' Daily Hours Of Work Or Rest, Certificate & Documentation - Documents, 1014, False, 01101, Cargo Ship Safety Equipment (including Exemption), Certificate & Documentation - Ship Certificates, 1003, Not Properly Filled, 99102, Other (solas Operational), Other, 1238, Other, 10109, Lights, Shapes, Sound-signals, Safety Of Navigation, 1082, Inoperative, 07106, Fire Detection And Alarm System, Fire Safety, 1011, Not As Required, 07105, Fire Doors/openings In Fire-resisting Divisions, Fire Safety, 1011, Not As Required, 11129, Operational Readiness Of Lifesaving Appliances, Life Saving Appliances, 1011, Not As Required, 15150, Ism, Ism, 1011, Not As Required, 07124, Maintenance Of Fire Protection Systems, Fire Safety, 1011, Not As Required, 18324, Cold Room, Cold Room Cleanliness, Cold Room Temperature, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 14121, Suspected Of Discharge Violation, Pollution Prevention - Marpol Annex I, 1011, Not As Required, 03110, Manholes/flush Scuttles, Water/weathertight Conditions, 1029, Corroded, 18424, Steam Pipes, Pressure Pipes, Wires (insulation), Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe, 02108, Electrical Installations In General, Structural Conditions, 1027, Unsafe, 14402, Sewage Treatment Plant, Pollution Prevention - Marpol Annex Iv, 1011, Not As Required, 08107, Machinery Controls Alarm, Alarms, 1082, Inoperative, 14811, Ballast Water Management System, Pollution Prevention - Ballast Water, 1100, Malfunctioning, 07115, Fire-dampers, Fire Safety, 1011, Not As Required, 14801, Ballast Water Management Plan, Pollution Prevention - Ballast Water, 1177, Incorrect
Inspection date
2021-06-09
Technical ism manager
-
Inspection authority
SPAIN
Address
Raboisen 5, 20095 , Hamburg, Philippines
Inspection port
Vigo
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
3
Deficiency description
14802, Ballast Water Record Book, Pollution Prevention - Ballast Water, 1003, Not Properly Filled, 14801, Ballast Water Management Plan, Pollution Prevention - Ballast Water, 1177, Incorrect, 15150, Ism, Ism, 1011, Not As Required,

Hamburg Way port map

© 2024 boatdb.
|