Home>Vessels>MYKONOS DAWN
Vessel

MYKONOS DAWN

MARSHALL ISLANDS
MH flag

Country

MH flag
MARSHALL ISLANDS

Year

2017

Status

Active

Vessel details

Vessel MMSI number

538006085

Vessel IMO number

9762481

Vessel type

CARGO

Vessel subtype

BULK CARRIER

Gross tonnage

23662

Deadweight

37880

Twenty-foot Equivalent Unit (TEU)

Not Available

Vessel length in meters

181

Vessel breadth in meters

30

Ship liquid gas capacity

-

Call sign

V7FO5

Current vessel live info

Last position info time - - -

Current draught of the vessel

-

Maximum draught of the vessel

-

Current reported speed of the vessel

-

Current vessel speed in knots

-

Maximum speed of the vessel

-

Vessel activity status

-

Current vessel longitude

-

Current vessel latitude

-

Current vessel course in degrees

-

Current vessel heading in degrees

-

Port name of the next planned stop

-

Estimated time of arrival in UTC

-

Owner company details

Company name
Lamda Maritime
Company type
INDEPENDENT SHIPPING
Country
GRC flagGreece
Address
38-40, Kapodistriou Avenue, Marousi, 151 23 Athens, Greece.
Parent company
Not Available
Parent company IMO
Not Available
Phone number
+30 210 68 54 617
Email
info@lamdamaritime.com
Website
https://www.lamdamaritime.com/
LinkedIn
Not Available

Casualities details

Ship casualties, including types of incidents, specific dates, and additional narrative details.
This vessel has never experienced any casualties.

Ship inspections

Inspection date
2022-12-28
Technical ism manager
-
Inspection authority
LATVIA
Address
Greece
Inspection port
Riga
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
-
Deficiency description
-
Inspection date
2022-02-22
Technical ism manager
-
Inspection authority
ITALY
Address
2, Rue Du Gabian, 98000, Monaco-ville, Greece
Inspection port
Bari
Phone
-
Inspection type
Detailed
Email
-
Detention
FALSE
Website
-
Ship deficiencies
1
Deficiency description
14108, 15 Ppm Alarm Arrangmts., Pollution Prevention - Marpol Annex I, 1011, Not As Required,
Inspection date
2022-02-14
Technical ism manager
-
Inspection authority
UKRAINE
Address
38-40, Kapodistriou Avenue, Marousi, 151 23 Athens, Greece.
Inspection port
Mykolaiv
Phone
+30 210 68 54 617
Inspection type
Initial
Email
info@lamdamaritime.com
Detention
FALSE
Website
https://www.lamdamaritime.com/
Ship deficiencies
-
Deficiency description
-
Inspection date
2021-03-15
Technical ism manager
-
Inspection authority
GERMANY
Address
Avenue Des Baumettes 7, 1020 , Renens, Greece
Inspection port
Hamburg
Phone
-
Inspection type
Detailed
Email
-
Detention
FALSE
Website
-
Ship deficiencies
33
Deficiency description
01220, Seafarers' Employment Agreement (sea), Certificate & Documentation - Crew Certificates, 1011, Not As Required, 01214, Endorsement By Flagstate, Certificate & Documentation - Crew Certificates, 1004, Expired, 18202, Legal Documentation On Work And Rest Hours, Labour Conditions - Conditions Of Employment, 1011, Not As Required, 15150, Ism, Ism, 1011, Not As Required, 01123, Continuous Synopsis Record, Certificate & Documentation - Ship Certificates, 1002, Entries Missing, 04109, Fire Drills, Emergency Systems, 1207, Lack Of Knowledge, 10112, Electronic Charts (ecdis), Safety Of Navigation, 1179, Not Updated, 11113, Launching Arrangements For Rescue Boats, Life Saving Appliances, 1011, Not As Required, 11129, Operational Readiness Of Lifesaving Appliances, Life Saving Appliances, 1011, Not As Required, 18419, Adequate Lighting - Mooring Arrangements, Labour Conditions - Health Protection, Medical Care, Social Security, 1082, Inoperative, 18407, Lighting (working Spaces), Labour Conditions - Health Protection, Medical Care, Social Security, 1082, Inoperative, 07105, Fire Doors/openings In Fire-resisting Divisions, Fire Safety, 1011, Not As Required, 07105, Fire Doors/openings In Fire-resisting Divisions, Fire Safety, 1011, Not As Required, 11104, Rescue Boats, Life Saving Appliances, 1026, Damaged, 11117, Lifebuoys Incl. Provision And Disposition, Life Saving Appliances, 1011, Not As Required, 18318, Food Temperature, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1023, Overheated, 18424, Steam Pipes, Pressure Pipes, Wires (insulation), Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe, 18313, Cleanliness, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 18424, Steam Pipes, Pressure Pipes, Wires (insulation), Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe, 10199, Other (navigation), Safety Of Navigation, 1238, Other, 07124, Maintenance Of Fire Protection Systems, Fire Safety, 1011, Not As Required, 07114, Remote Means Of Control (opening,pumps,ventilation,etc.) Machinery Spaces, Fire Safety, 1011, Not As Required, 07114, Remote Means Of Control (opening,pumps,ventilation,etc.) Machinery Spaces, Fire Safety, 1011, Not As Required, 07105, Fire Doors/openings In Fire-resisting Divisions, Fire Safety, 1011, Not As Required, 07199, Other (fire Safety), Fire Safety, 1238, Other, 14402, Sewage Treatment Plant, Pollution Prevention - Marpol Annex Iv, 1011, Not As Required, 13103, Gauges,thermometers, Etc, Propulsion And Auxiliary Machinery, 1082, Inoperative, 13103, Gauges,thermometers, Etc, Propulsion And Auxiliary Machinery, 1082, Inoperative, 08109, Boiler Alarm, Alarms, 1082, Inoperative, 02108, Electrical Installations In General, Structural Conditions, 1011, Not As Required, 13103, Gauges,thermometers, Etc, Propulsion And Auxiliary Machinery, 1011, Not As Required, 13103, Gauges,thermometers, Etc, Propulsion And Auxiliary Machinery, 1011, Not As Required, 13103, Gauges,thermometers, Etc, Propulsion And Auxiliary Machinery, 1082, Inoperative
Inspection date
2021-01-22
Technical ism manager
-
Inspection authority
LITHUANIA
Address
Langenstrasse 44, 28195 , Bremen, Greece
Inspection port
Klaipeda
Phone
-
Inspection type
Detailed
Email
-
Detention
FALSE
Website
-
Ship deficiencies
-
Deficiency description
-