Home>Vessels>NCC DALIA
Vessel

NCC DALIA

PANAMA
PA flag

Country

PA flag
PANAMA

Year

2014

Status

Active

Vessel details

Vessel MMSI number

356673000

Vessel IMO number

9480162

Vessel type

TANKER

Vessel subtype

OIL OR CHEMICAL TANKER

Gross tonnage

29168

Deadweight

45562

Twenty-foot Equivalent Unit (TEU)

Not Available

Vessel length in meters

182.98

Vessel breadth in meters

32.23

Ship liquid gas capacity

-

Call sign

3FHT6

Current vessel live info

Last position info time - - -

Current draught of the vessel

-

Maximum draught of the vessel

-

Current reported speed of the vessel

-

Current vessel speed in knots

-

Maximum speed of the vessel

-

Vessel activity status

-

Current vessel longitude

-

Current vessel latitude

-

Current vessel course in degrees

-

Current vessel heading in degrees

-

Port name of the next planned stop

-

Estimated time of arrival in UTC

-

Owner company details

Company name
Uacc Bergshav Tanker
Company type
OPERATOR / CONTROL
Country
UAE flagNot Available
Address
C/o United Arab Chemical Carriers Ltd , Suite 08, Level 23, Emirates Financial Towers (south), Dubai International Financial Centre, Po Box 125445, Dubai, United Arab Emirates
Parent company
UNITED ARAB CHEMICAL CARRIERS LTD. (UACC)
Parent company IMO
5579451
Phone number
+971 4 387 9878
Email
info@uacc.ae
Website
http://www.uacc.ae
LinkedIn
Not Available

Casualities details

Ship casualties, including types of incidents, specific dates, and additional narrative details.
This vessel has never experienced any casualties.

Ship inspections

Inspection date
2024-01-29
Technical ism manager
Synergy Navis Marine Pvt Ltd
Inspection authority
FRANCE
Address
33rd Floor, Onyx, North Main Road, Koregaon Park, Pune, Maharashtra, 411001, India.
Inspection port
Nantes-saint Nazaire (gpm)
Phone
+91 20 6707 3000
Inspection type
Detailed
Email
mail@synergynavis.com
Detention
FALSE
Website
-
Ship deficiencies
1
Deficiency description
Fire Safety; 07105 - Fire Doors/openings In Fire-resisting Divisions; Inoperative
Inspection date
2023-09-26
Technical ism manager
-
Inspection authority
JAPAN
Address
33rd Floor, Onyx, North Main Road, Koregaon Park, Pune, Maharashtra, 411001, India.
Inspection port
Osaka
Phone
+91 20 6707 3000
Inspection type
Initial
Email
mail@synergynavis.com
Detention
FALSE
Website
-
Ship deficiencies
4
Deficiency description
1 01306 Certificate And Documentation - Documents (schedules For Watchkeeping Personnel) No 2 11132 Life Saving Appliances (maintenance And Inspections) No 3 01336 Certificate And Documentation - Documents (certificate Or Documentary Evidence Of Financi
Inspection date
2022-11-21
Technical ism manager
-
Inspection authority
NIGERIA
Address
33rd Floor, Onyx, North Main Road, Koregaon Park, Pune, Maharashtra, 411001, India.
Inspection port
Apapa-lagos
Phone
+91 20 6707 3000
Inspection type
Initial
Email
mail@synergynavis.com
Detention
FALSE
Website
-
Ship deficiencies
-
Deficiency description
-
Inspection date
2022-09-28
Technical ism manager
-
Inspection authority
BELGIUM
Address
North Main Road, Koregaon Park, Pune, India
Inspection port
Antwerpen
Phone
-
Inspection type
Detailed
Email
-
Detention
FALSE
Website
-
Ship deficiencies
29
Deficiency description
14108, 15 Ppm Alarm Arrangmts., Pollution Prevention - Marpol Annex I, 1011, Not As Required, 13101, Propulsion Main Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required, 08108, Ums - Alarms, Alarms, 1100, Malfunctioning, 18316, Water, Pipes, Tanks, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 02105, Steering Gear, Structural Conditions, 1011, Not As Required, 04121, Crew Familiarization With Emergency Systems, Emergency Systems, 1011, Not As Required, 11112, Launching Arrangements For Survival Craft, Life Saving Appliances, 1086, Not Properly Maintained, 11113, Launching Arrangements For Rescue Boats, Life Saving Appliances, 1086, Not Properly Maintained, 04103, Emergency, Lighting,batteries And Switches, Emergency Systems, 1082, Inoperative, 04103, Emergency, Lighting,batteries And Switches, Emergency Systems, 1011, Not As Required, 08108, Ums - Alarms, Alarms, 1100, Malfunctioning, 10105, Magnetic Compass, Safety Of Navigation, 1011, Not As Required, 10112, Electronic Charts (ecdis), Safety Of Navigation, 1179, Not Updated, 10118, Speed And Distance Indicator, Safety Of Navigation, 1082, Inoperative, 18324, Cold Room, Cold Room Cleanliness, Cold Room Temperature, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 10103, Radar, Safety Of Navigation, 1082, Inoperative, 10116, Nautical Publications, Safety Of Navigation, 1000, Missing, 05107, Maintenance/duplication Of Equipment, Radio Communications, 1011, Not As Required, 12199, Other (tankers), Dangerous Goods, 1238, Other, 07199, Other (fire Safety), Fire Safety, 1238, Other, 11101, Lifeboats, Life Saving Appliances, 1086, Not Properly Maintained, 03108, Ventilators, Air Pipes, Casings, Water/weathertight Conditions, 1029, Corroded, 03105, Covers (hatchway-, Portable-, Tarpaulins, Etc.), Water/weathertight Conditions, 1086, Not Properly Maintained, 02199, Other (structural Conditions), Structural Conditions, 1238, Other, 18302, Sanitary Facilities, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1082, Inoperative, 15150, Ism, Ism, 1011, Not As Required, 02108, Electrical Installations In General, Structural Conditions, 1011, Not As Required, 02108, Electrical Installations In General, Structural Conditions, 1011, Not As Required, Other, Other, Other, Other, Other
Inspection date
2021-10-01
Technical ism manager
-
Inspection authority
NETHERLANDS
Address
27th Floor, South Island Place, 8, Wong Chuk Hang Road, Southern, Hong Kong, China
Inspection port
Rotterdam
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
-
Deficiency description
-

Ncc Dalia port map