Home>Vessels>NEW ASSIMINA
Vessel

NEW ASSIMINA

LIBERIA
LR flag

Country

LR flag
LIBERIA

Year

2009

Status

Active

Vessel details

Vessel MMSI number

636014441

Vessel IMO number

9469546

Vessel type

CARGO

Vessel subtype

BULK CARRIER

Gross tonnage

93360

Deadweight

182060

Twenty-foot Equivalent Unit (TEU)

Not Available

Vessel length in meters

292

Vessel breadth in meters

45.04

Ship liquid gas capacity

-

Call sign

A8TV9

Current vessel live info

Last position info time - - -

Current draught of the vessel

-

Maximum draught of the vessel

-

Current reported speed of the vessel

-

Current vessel speed in knots

-

Maximum speed of the vessel

-

Vessel activity status

-

Current vessel longitude

-

Current vessel latitude

-

Current vessel course in degrees

-

Current vessel heading in degrees

-

Port name of the next planned stop

-

Estimated time of arrival in UTC

-

Owner company details

Company name
Unisea Shipping
Company type
OWNER
Country
GRC flagGreece
Address
4, Xenias Street, Kifisia, 145 62 Athens, Greece
Parent company
Not Available
Parent company IMO
Not Available
Phone number
+30 210 4591 860
Email
Website
http://www.unisea.gr
LinkedIn
Not Available

Casualities details

Ship casualties, including types of incidents, specific dates, and additional narrative details.
This vessel has never experienced any casualties.

Ship inspections

Inspection date
2023-11-20
Technical ism manager
-
Inspection authority
CHINA
Address
57a, Poseidonos Avenue, Moschato, 183 44 Piraeus, Greece
Inspection port
Dongjiakou
Phone
+30 210 429 0218
Inspection type
Initial
Email
Detention
FALSE
Website
-
Ship deficiencies
1
Deficiency description
03108; Water/weathertight Conditions (ventilators, Air Pipes, Casings)
Inspection date
2023-03-17
Technical ism manager
-
Inspection authority
UNITED STATES OF AMERICA
Address
-
Inspection port
Baltimore, Maryland
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
8
Deficiency description
System: 02 - Structural Conditions Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: A Means For Securing And Maintaining Weather Tightness Shall Be The To The Satisfaction Of The Administration. Psco Observed That Both Bos’n Storage Watertight Doorways With Daylight Visible Through Its Seals When Secured. Icll 16.4 Due Date: N/a Deficiency Resolved? Yes Resolved Date: 3/24/2023 12:00:00 Am Resolution Description: Received Class Report Atesting To The Proper Repairs On Watertight Doors. System: 09 - Working And Living Conditions Sub-system: 092 - Working Conditions Cause: Description Of Deficiency: All Electrical Apparatus Shall Be So Constructed And So Installed As Not To Cause Injury When Handled Or Touched In A Normal Manner. Psco Observed Improper Connections And Loose Wires In The Purifier Room And Emergency Generator Room Junction Boxes. 74 Solas (20) Ii-2/45.1.3 Due Date: N/a Deficiency Resolved? Yes Resolved Date: 3/24/2023 12:00:00 Am Resolution Description: Received Class Report Atesting To The Proper Repairs Of Lose Wires And Conections. System: 07 - Fire Safety Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: Fire Protection Systems And Fire-fighting Systems And Appliances Shall Be Maintained Ready For Use. In The Steering Gear Room The Psco Observed The Four Motor Controllers For The Vessel’s Whole Ship Fire Water Mist System Had Faults And Appear To Be Non-operational. In The Vessel’s Fire Control Station Within In The Water Mist Panel Circuit 4k5 Was Found Tripped. The Operational Condition Of These Systems Is Unknown. Additionally Fire Extingusiher #230 Adjacent To The Incinerator Was Found Without A Charge. 74 Solas (20) Ii-2/14.2.1.2 Due Date: N/a Deficiency Resolved? Yes Resolved Date: 3/24/2023 12:00:00 Am Resolution Description: Received Class Report Attesting To The Replacement Of Fire Extinguisher. System: 07 - Fire Safety Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: Means Shall Be Provided To Control Leaks Of Flammable Liquids. Psco Observed Excessive Oil Leaks On Main Engine, Diesel Generators, Deck Air Compressor And, Sludge Mixing Tank. Rags And Plastic Catch Basins Were Being Used To Maintain The Oil Creating A Fire Hazardous Condition. 74 Solas (20) Ii-2/4.1.1 Due Date: N/a Deficiency Resolved? Yes Resolved Date: 3/24/2023 12:00:00 Am Resolution Description: Received Class Report Attesting To The Rectification Of Excessive Oil Leaks. System: 07 - Fire Safety Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: Oil Fuel Pipes, Which If Damaged, Would Allow Oil To Escape From A Storage, Settling Or Daily Service Tank Having A Capacity Of 500 L And Above Situated Above The Double Bottom, Shall Be Fitted With A Cock Or Valve Directly On The Tank Capable Of Being Closed From A Safe Position Outside The Space Concerned In The Event Of A Fire Occurring In The Space In Which Such Tanks Are Situated. Psco Observed The Vessel's Hydraulic Quick Closing Valves Lacked Adequate Oil In Their Oil Level Sight Glass On All Quick Closing Actuator Valves. Vessel's Crew Attempted To Operate Actuator 16, Per Request Of The Psco, For Approximately 15 Minutes Without Success. The Quick Closing Valve In Operation Was Made Worse By The Observation Of Excessive Oil Leaks Throughout The Engine Room And Concerns For The Operational Status Of The Vessel's Fixed Fire Fighting System. 74 Solas (20) 11-2/4.2.2.3.4 Due Date: 3/24/2023 12:00:00 Am Deficiency Resolved? Yes Resolved Date: 3/24/2023 12:00:00 Am Resolution Description: Received Class Report Attesting To The Repairs And Proper Operation Of The Quick Closing Valves. System: 14 - Pollution Prevention Sub-system: 141 - Marpol Annex I Cause: Description Of Deficiency: The Arrangement On Board The Ship For The Extraction Of Samples From The 15ppm Bilge Alarm Should Give A Truly Representative Sample Of The Effluent With Adequate Pressure And Flow. Psco Observed That The Vessel’s Ows Sample Line Had A Solenoid Controlled Three Way Valve, A Manually Controlled Ball Valve And A Three Way Valve On The Content Meter And A Ball Valve On The Effluent Discharge Line. The Vessel’s Approved Line Drawing Did Not Have Either Of These Ball Valves Installed. These Manually Operated Ball Valves Could Be Used To Trap Clean Water Within The Content Meter. In Addition, The Vessel’s Ocm’s Desiccant Was Exhausted, Potentially Impacting The Optical Sensor From Operating Correctly. Marpol (73/78) I/14.7, Mepc.107 (49) 6.2.2 Due Date: N/a Deficiency Resolved? Yes Resolved Date: 3/24/2023 12:00:00 Am Resolution Description: Received Class Report Stating That Additional Valves Have Been Removed. System: 15 - Safety Management Systems (ism) Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: The Company Should Establish Procedures, Plans And Instructions, Including Checklists As Appropriate, For Key Shipboard Operations Concerning The Safety Of The Personnel, Ship And Protection Of The Environment(7). The Company Should Ensure That Any Non-conformity Is Reported. The Vessel's Sms States That When The Vessel Operates With A Fully Manned Engine, And Before The Relieving Engineer Comes On Watch, They Shall Make A Complete Round Of The Engine Room Using Form Fl1 7-engine Checklist. Chief Engineer Was Not Able To Provide Evidence Of Rounds Being Completed Or Any Notification Of Discrepancies Identified During The Rounds Conducted By The Crew. The Chief Engineer Also Stated That The Crew Uses The Engine Log Book To Document Maintenance Items To Be Conducted. However, None Of The Discrepancies Identified During The Exam As Described In Deficiencies #2 Through #8 Were Noted In The Engine Log Book. This Provides Evidence Of A Serious Lack Of Effectiveness Of The Vessel's Sms. 74 Solas (20) Ix/3.1, Ism Code 7 & 10.2.2 Due Date: 3/24/2023 12:00:00 Am Deficiency Resolved? Yes Resolved Date: 3/24/2023 12:00:00 Am Resolution Description: Received Audit Report. All Mncs Were Downgraded. System: 07 - Fire Safety Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: The Following Fire Protection Shall Be Kept In Good Order So As To Ensure Their Required Performance If A Fire Occurs; (1) Structural Fire Protection, Including Fire Resisting Divisions, And Protection Of Openings And Penetrations In These Divisions. Psco Observed Wasted Ventilation Ducting In The Vessel’s Purifier Room. 74 Solas (20) Ii-2/14.2.1.1.1 Due Date: N/a Deficiency Resolved? Yes Resolved Date: 3/24/2023 12:00:00 Am Resolution Description: Received Class Report Attesting To The Proper Repairs Of The Ventilation Duckting.
Inspection date
2022-10-19
Technical ism manager
-
Inspection authority
VIETNAM
Address
Gildo Pastor Center, 7, Rue Du Gabian, 98000 Monte Carlo, Monaco
Inspection port
Quangninh
Phone
+377 97985900
Inspection type
Initial
Email
Detention
FALSE
Website
https://ctmmc.com/
Ship deficiencies
-
Deficiency description
-
Inspection date
2022-10-19
Technical ism manager
-
Inspection authority
VIETNAM
Address
-
Inspection port
Quangninh
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
-
Deficiency description
-
Inspection date
2022-05-18
Technical ism manager
-
Inspection authority
AUSTRALIA
Address
-
Inspection port
Abbot Point
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
3
Deficiency description
1 11101 Life Saving Appliances (lifeboats) No 2 07106 Fire Safety (fire Detection And Alarm System) No 3 13199 Propulsion And Auxiliary Machinery (other (machinery)) No
Inspection date
2022-05-18
Technical ism manager
-
Inspection authority
AUSTRALIA
Address
-
Inspection port
Abbot Point
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
-
Deficiency description
-

New Assimina port map