Home>Vessels>PAC CANOPUS
Vessel

PAC CANOPUS

SINGAPORE
SG flag

Country

SG flag
SINGAPORE

Year

2013

Status

Active

Vessel details

Vessel MMSI number

566846000

Vessel IMO number

9638630

Vessel type

CARGO

Vessel subtype

GENERAL CARGO

Gross tonnage

20886

Deadweight

27263

Twenty-foot Equivalent Unit (TEU)

1391

Vessel length in meters

179.5

Vessel breadth in meters

27.2

Ship liquid gas capacity

-

Call sign

9V9787

Current vessel live info

Last position info time - - -

Current draught of the vessel

-

Maximum draught of the vessel

-

Current reported speed of the vessel

-

Current vessel speed in knots

-

Maximum speed of the vessel

-

Vessel activity status

-

Current vessel longitude

-

Current vessel latitude

-

Current vessel course in degrees

-

Current vessel heading in degrees

-

Port name of the next planned stop

-

Estimated time of arrival in UTC

-

Owner company details

Company name
Pacific International Lines (singapore)
Company type
INDEPENDENT SHIPPING
Country
SNG flagNot Available
Address
Pil Building, 140 Cecil Street, Singapore 069540
Parent company
Not Available
Parent company IMO
Not Available
Phone number
+65 62218133
Email
general@sgp.pilship.com
Website
http://www.pilship.com
LinkedIn
Not Available

Casualities details

Ship casualties, including types of incidents, specific dates, and additional narrative details.
Casualty date
2021-03-05
Casualty type
Mechanical Fault
Casualty details
Vessel reported technical failure and went adrift, while sailing downstream on the Weser, en route from Bremen to Nantes in ballast on 05 Mar 2021. Tugs Baer and RT Emotion assisted and pulled it into Bremerhaven safely about 4 hrs later.

Ship inspections

Inspection date
2023-12-03
Technical ism manager
-
Inspection authority
INDONESIA
Address
1 Kim Seng Promenade, #07-02 Great World City singapore, 237994 Singapore
Inspection port
Teluk Bayur
Phone
+65 6733 3500
Inspection type
Initial
Email
tech@paccship.com.sg
Detention
FALSE
Website
http://www.pclsg.com/
Ship deficiencies
-
Deficiency description
-
Inspection date
2023-08-17
Technical ism manager
-
Inspection authority
SLOVENIA
Address
Singapore
Inspection port
Koper
Phone
-
Inspection type
Detailed
Email
-
Detention
FALSE
Website
-
Ship deficiencies
3
Deficiency description
07113, Fire Pumps And Its Pipes, Fire Safety, 1011, Not As Required, 07109, Fixed Fire Extinguishing Installation, Fire Safety, 1011, Not As Required, 10128, Navigation Bridge Visibility, Safety Of Navigation, 1011, Not As Required
Inspection date
2023-07-22
Technical ism manager
-
Inspection authority
INDONESIA
Address
1 Kim Seng Promenade, #07-02 Great World City singapore, 237994 Singapore
Inspection port
Teluk Bayur
Phone
+65 6733 3500
Inspection type
Initial
Email
tech@paccship.com.sg
Detention
FALSE
Website
http://www.pclsg.com/
Ship deficiencies
-
Deficiency description
-
Inspection date
2023-01-25
Technical ism manager
-
Inspection authority
INDONESIA
Address
1 Kim Seng Promenade, #07-02 Great World City singapore, 237994 Singapore
Inspection port
Palembang
Phone
+65 6733 3500
Inspection type
Initial
Email
tech@paccship.com.sg
Detention
FALSE
Website
http://www.pclsg.com/
Ship deficiencies
-
Deficiency description
-
Inspection date
2022-07-15
Technical ism manager
-
Inspection authority
INDONESIA
Address
1 Kim Seng Promenade, #07-02 Great World City singapore, 237994 Singapore
Inspection port
Teluk Bayur
Phone
+65 6733 3500
Inspection type
Initial
Email
tech@paccship.com.sg
Detention
FALSE
Website
http://www.pclsg.com/
Ship deficiencies
-
Deficiency description
-
Inspection date
2022-02-03
Technical ism manager
-
Inspection authority
INDONESIA
Address
-
Inspection port
Teluk Bayur
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
-
Deficiency description
-
Inspection date
2021-03-05
Technical ism manager
-
Inspection authority
GERMANY
Address
68, Glassford Street, Glasgow, Singapore
Inspection port
Bremerhaven
Phone
-
Inspection type
Detailed
Email
-
Detention
FALSE
Website
-
Ship deficiencies
1
Deficiency description
13101, Propulsion Main Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required,
Inspection date
2021-03-05
Technical ism manager
-
Inspection authority
GERMANY
Address
68, Glassford Street, Glasgow, Singapore
Inspection port
Bremerhaven
Phone
-
Inspection type
Detailed
Email
-
Detention
FALSE
Website
-
Ship deficiencies
1
Deficiency description
13101, Propulsion Main Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required,
Inspection date
2021-02-09
Technical ism manager
-
Inspection authority
BELGIUM
Address
Gongping Lu, Hongkou Qu, Shanghai, China
Inspection port
Antwerpen
Phone
-
Inspection type
Detailed
Email
-
Detention
FALSE
Website
-
Ship deficiencies
43
Deficiency description
02109, Permanent Means Of Access, Structural Conditions, 1027, Unsafe, 15150, Ism, Ism, 1011, Not As Required, 02109, Permanent Means Of Access, Structural Conditions, 1086, Not Properly Maintained, 07111, Personal Equipment For Fire Safety, Fire Safety, 1011, Not As Required, 18401, Medical Equipment, Medical Chest, Medical Guide, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 05111, Satellite Epirb 406mhz/1.6ghz, Radio Communications, 1011, Not As Required, 07106, Fire Detection And Alarm System, Fire Safety, 1011, Not As Required, 07106, Fire Detection And Alarm System, Fire Safety, 1011, Not As Required, 18315, Provisions Quality And Nutritional Value, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 07108, Ready Availability Of Fire Fighting Equipment, Fire Safety, 1045, Not Properly Stowed, 07105, Fire Doors/openings In Fire-resisting Divisions, Fire Safety, 1011, Not As Required, 07101, Fire Prevention Structural Integrity, Fire Safety, 1075, Inadequate, 18324, Cold Room, Cold Room Cleanliness, Cold Room Temperature, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 18312, Galley, Handlingroom (maintenance), Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 04106, Emergency Steering Position Com./ Compass Reading, Emergency Systems, 1082, Inoperative, 07108, Ready Availability Of Fire Fighting Equipment, Fire Safety, 1045, Not Properly Stowed, 07114, Remote Means Of Control (opening,pumps,ventilation,etc.) Machinery Spaces, Fire Safety, 1082, Inoperative, 04114, Emergency Source Of Power - Emergency Generator, Emergency Systems, 1011, Not As Required, 10126, Record Of Drills And Steering Gear Tests, Safety Of Navigation, 1011, Not As Required, 11104, Rescue Boats, Life Saving Appliances, 1026, Damaged, 14102, Retention Of Oil On Board, Pollution Prevention - Marpol Annex I, 1011, Not As Required, 18418, Winches & Capstans, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 18326, Laundry, Adequate Locker, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 02101, Closing Devices/watertight Doors, Structural Conditions, 1011, Not As Required, 03103, Railing, Gangway, Walkway And Means For Safe Passage, Water/weathertight Conditions, 1026, Damaged, 02107, Ballast, Fuel And Other Tanks, Structural Conditions, 1011, Not As Required, 18327, Ventilation (working Spaces), Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 07123, Operation Of Fire Protection Systems, Fire Safety, 1011, Not As Required, 18409, Dangerous Areas, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe, 07114, Remote Means Of Control (opening,pumps,ventilation,etc.) Machinery Spaces, Fire Safety, 1011, Not As Required, 11103, Stowage And Provision Of Lifeboats, Life Saving Appliances, 1011, Not As Required, 13104, Bilge Pumping Arrangements, Propulsion And Auxiliary Machinery, 1082, Inoperative, 99102, Other (solas Operational), Other, 1238, Other, 07113, Fire Pumps And Its Pipes, Fire Safety, 1110, Insufficient Pressure, 04117, Functionality Of Safety Systems, Emergency Systems, 1011, Not As Required, 04121, Crew Familiarization With Emergency Systems, Emergency Systems, 1011, Not As Required, 13102, Auxiliary Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required, 07114, Remote Means Of Control (opening,pumps,ventilation,etc.) Machinery Spaces, Fire Safety, 1011, Not As Required, 18313, Cleanliness, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 03112, Scuppers, Inlets And Discharges, Water/weathertight Conditions, 1011, Not As Required, 04102, Emergency Fire Pump And Its Pipes, Emergency Systems, 1082, Inoperative, 10101, Pilot Ladders And Hoist/pilot Transfer Arrangements, Safety Of Navigation, 1027, Unsafe, 18318, Food Temperature, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1023, Overheated

Pac Canopus port map