Home>Vessels>PUERTO ROSARIO
Vessel

PUERTO ROSARIO

PANAMA
PA flag

Country

PA flag
PANAMA

Year

2014

Status

Active

Vessel details

Vessel MMSI number

356493000

Vessel IMO number

9656084

Vessel type

CARGO

Vessel subtype

BULK CARRIER

Gross tonnage

36353

Deadweight

64689

Twenty-foot Equivalent Unit (TEU)

Not Available

Vessel length in meters

199.9

Vessel breadth in meters

32.32

Ship liquid gas capacity

-

Call sign

H8AI

Current vessel live info

Last position info time - - -

Current draught of the vessel

-

Maximum draught of the vessel

-

Current reported speed of the vessel

-

Current vessel speed in knots

-

Maximum speed of the vessel

-

Vessel activity status

-

Current vessel longitude

-

Current vessel latitude

-

Current vessel course in degrees

-

Current vessel heading in degrees

-

Port name of the next planned stop

-

Estimated time of arrival in UTC

-

Owner company details

Company name
Lomar Corp
Company type
OWNER
Country
BER flagBermuda
Address
3rd Floor, Par La Ville Place, 14, Par La Ville Road, Hamilton, Bermuda
Parent company
Not Available
Parent company IMO
Not Available
Phone number
+1 441 292 7796
Email
fleet@lomarshipping.com
Website
http://www.lomarshipping.com
LinkedIn
https://www.linkedin.com/company/lomar-shipping/

Casualities details

Ship casualties, including types of incidents, specific dates, and additional narrative details.
This vessel has never experienced any casualties.

Ship inspections

Inspection date
2024-01-20
Technical ism manager
-
Inspection authority
CHINA
Address
Glockengiesserwall 3, 20095 Hamburg
Inspection port
Rizhao
Phone
+49 40 3096740
Inspection type
Initial
Email
germany@uniteammarine.com
Detention
FALSE
Website
https://www.uniteammarine.com/
Ship deficiencies
6
Deficiency description
Safety Of Navigation (lights, Shapes, Sound-signals) no 2 04103 emergency Systems (emergency, Lighting,batteries And Switches) no 3 10109 safety Of Navigation (lights, Shapes, Sound-signals) no 4 14199 pollution Prevention - Marpol Annex I (other (marpol Annex I)) no 5 11117 life Saving Appliances (lifebuoys Incl. Provision And Disposition) no 6 10109 safety Of Navigation (lights, Shapes, Sound-signals)
Inspection date
2023-09-21
Technical ism manager
Uniteam Marine Shipping (gmbh)
Inspection authority
UNITED STATES OF AMERICA
Address
-
Inspection port
St Petersburg, Florida
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
4
Deficiency description
System: 02 - Structural Conditions Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: 02105 - Structural Conditions - All Steering Gear Components And The Rudder Stock Shall Be Of Sound And Reliable Construction To The Satisfaction Of The Administration. Psco Observed An Oil Sheen Originating From The Stern Of The Vessel. After An Underwater Diver Survey, It Was Determined The Rudder Seals Of The Vessel Had Failed, Resulting In The Discharge Of Oil From The Vessel. 74solas(20)ii-1/29.2.1, 15ac Due Date: N/a Deficiency Resolved? Yes Resolved Date: 9/28/2023 12:00:00 Am Resolution Description: N/a System: 03 - Water/weathertight Conditions Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: 03199 - Water/weathertight Conditions - The Ring, Lines And Letters Shall Be Painted In White Or Yellow On A Dark Ground Or In Black On A Light Ground. Psco Observed Starboard Side Deck Line Not Contrasting In Color. Icl I/8, 16ac Due Date: N/a Deficiency Resolved? Yes Resolved Date: 9/28/2023 12:00:00 Am Resolution Description: Received Class Survey Resolving The Issue System: 07 - Fire Safety Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: 07115 - Fire Safety - The Following Fire Protection Systems Shall Be Kept In Good Order...structural Fire Protection, Including Fire-resisting Divisions, And Protection Of Openings And Penetrations In These Divisions. Psco Observed Fire Dampers In Upper Fan Room Were Corroded And Bent, Which Would Allow For The Passage Of Flames And Smoke In The Event Of A Fire. 74solas(20)ii-2/14.2.1.1.1, 15ac Due Date: N/a Deficiency Resolved? Yes Resolved Date: 9/28/2023 12:00:00 Am Resolution Description: Received Class Survey Resolving The Issue System: 07 - Fire Safety Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: 07126 - Fire Safety - The Purpose Of This Regulation Is To Prevent The Ignition Of Combustible Materials Or Flammable Liquids. For This Purpose, The Following Function Requirements Shall Be Met. Psco Observed Oil Soaked Lagging In The Vicinity Of The #4 Cylinder On Main Engine. 74solas(20)ii-1/4.1.1, 15ac Due Date: N/a Deficiency Resolved? Yes Resolved Date: 9/28/2023 12:00:00 Am Resolution Description: Received Class Survey Resolving The Issue
Inspection date
2022-03-15
Technical ism manager
-
Inspection authority
INDONESIA
Address
-
Inspection port
Meulaboh
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
1
Deficiency description
Life Saving Appliances (lifebuoys Incl. Provision And Disposition)

Puerto Rosario port map

© 2024 boatdb.
|