Ship casualties, including types of incidents, specific dates, and additional narrative details.
This vessel has never experienced any casualties.
Ship inspections
Inspection date
2024-01-10
Technical ism manager
Angelakos (hellas) Sa
Inspection authority
UNITED STATES OF AMERICA
Address
-
Inspection port
New Orleans
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
1
Deficiency description
System: 13 - Propulsion And Auxiliary Machinery Sub-system: N/a - No Subsystem Cause: Improper/lack Of Maintenance Description Of Deficiency: The Machinery, Boilers, And Other Pressure Vessels Associated Piping System And Fittings Shall Be Of A Design And Construction Adequate For Service. Psco Observed #4 And #6 P.c.o. Non Flow Alarm Showwing In Alarm In Ecr. 74 Solas(20) Ii-1/26 Due Date: N/a Deficiency Resolved? Yes Resolved Date: 1/17/2024 12:00:00 Am Resolution Description: Recieved Class Report Stating Satisifactory Resolution Of Defective Items.
1 06107 Cargo Operations Including Equipment (cargo Operation) No 2 15106 Ism (shipboard Operations) No 3 13101 Propulsion And Auxiliary Machinery (propulsion Main Engine) No 4 07123 Fire Safety (operation Of Fire Protection Systems) No
Cargo Operations Including Equipment (cargo Operation); Ism (shipboard Operations); Propulsion And Auxiliary Machinery (propulsion Main Engine); Fire Safety (operation Of Fire Protection Systems)
Cargo Operations Including Equipment (cargo Operation) ; Ism (shipboard Operations) ; Safety Of Navigation (electronic Charts (ecdis) ) ; Propulsion And Auxiliary Machinery (propulsion Main Engine) ; Fire Safety (operation Of Fire Protection Systems)