Home>Vessels>SSI DEFIANT
Vessel

SSI DEFIANT

MARSHALL ISLANDS
MH flag

Country

MH flag
MARSHALL ISLANDS

Year

2013

Status

Active

Vessel details

Vessel MMSI number

538010156

Vessel IMO number

9603116

Vessel type

CARGO

Vessel subtype

BULK CARRIER

Gross tonnage

32987

Deadweight

56489

Twenty-foot Equivalent Unit (TEU)

Not Available

Vessel length in meters

189.99

Vessel breadth in meters

32.28

Ship liquid gas capacity

-

Call sign

V7A5690

Current vessel live info

Last position info time - - -

Current draught of the vessel

-

Maximum draught of the vessel

-

Current reported speed of the vessel

-

Current vessel speed in knots

-

Maximum speed of the vessel

-

Vessel activity status

-

Current vessel longitude

-

Current vessel latitude

-

Current vessel course in degrees

-

Current vessel heading in degrees

-

Port name of the next planned stop

-

Estimated time of arrival in UTC

-

Owner company details

Company name
Unknown
Company type
OWNER
Country
UNK flagUnited Nations Interim Administration Mission in Kosovo
Address
Not Available
Parent company
Not Available
Parent company IMO
Not Available
Phone number
Not Available
Email
Not Available
Website
Not Available
LinkedIn
Not Available

Casualities details

Ship casualties, including types of incidents, specific dates, and additional narrative details.
This vessel has never experienced any casualties.

Ship inspections

Inspection date
2023-12-29
Technical ism manager
-
Inspection authority
CHINA
Address
Uunit 1206 B, Cluster E, Saba 1 Tower, Jumeirah Lakes Towers, Dubai, United Arab Emirates
Inspection port
Taizhou, Jiangsu
Phone
+971 4 368 7218
Inspection type
Follow-up
Email
safety@densay.com
Detention
FALSE
Website
-
Ship deficiencies
1
Deficiency description
Fire Safety (fire Fighting Equipment And Appliances) (28.12.2023)
Inspection date
2023-12-28
Technical ism manager
-
Inspection authority
CHINA
Address
-
Inspection port
Taizhou, Jiangsu
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
3
Deficiency description
1 11108 life Saving Appliances (inflatable Liferafts) no 2 07115 fire Safety (fire-dampers) no 3 07110 fire Safety (fire Fighting Equipment And Appliances) no
Inspection date
2023-10-13
Technical ism manager
Densay Ship Management & Technical Services Dmcc
Inspection authority
UNITED STATES OF AMERICA
Address
-
Inspection port
New Orleans
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
8
Deficiency description
System: 05 - Radio Communications Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: All Equipment To Which This Chapter Applies Shall Be A Type Approved By The Administration. Psco Witnessed Temp Wiring Connection From Navtex To Ecdis. 74 Solas (2020) Iv/14.1, Code 16 Due Date: 10/27/2023 12:00:00 Am Deficiency Resolved? Yes Resolved Date: 10/20/2023 12:00:00 Am Resolution Description: Received, Reviewed And Accepted Class Report / Proper Documentation From Bureau Veritas Stating The Deficienciency Was Rectified. System: 07 - Fire Safety Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: Cargo Spaces On Cargo Ships Shall Be Protected By A Fixed Co2 System Complying With The Fss Code. The Piping For The Distribution Of Co2 Shall Have System Flow Calculations Performed Using A Calculation Technique Acceptable To The Administration. Psco Witnessed Repairs To Co2 Line On Ch #5 Portside With Non-matching Pipe Sizing Inserted Intermittently With Fillet Welds. Prove Acceptance Of Arrangement To Cognizant Captain Of The Port. 74 Solas (2020) Ii-2/7.1.2, Fss Code 5.2.1.2.1, Code 17, Ptd Due Date: 10/13/2023 12:00:00 Am Deficiency Resolved? Yes Resolved Date: 10/20/2023 12:00:00 Am Resolution Description: Received, Reviewed And Accepted Class Report / Proper Documentation From Bureau Veritas Stating The Deficienciency Was Rectified. System: 11 - Life Saving Appliances Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: Each Survival Craft Shall Be Stowed In A State Of Continuous Readiness So That Two Crew Members Can Launch In Less Than 5 Minutes. Psco Waited More Than 5 Minutes For Two Crew Members To Start Rescue Boat Engine, But It Would Not Start. 74 Solas (2020) Iii/13.1.3, Code 17, Ptd Due Date: 10/13/2023 12:00:00 Am Deficiency Resolved? Yes Resolved Date: 10/20/2023 12:00:00 Am Resolution Description: Received, Reviewed And Accepted Class Report / Proper Documentation From Bureau Veritas Stating The Deficienciency Was Rectified. System: 09 - Working And Living Conditions Sub-system: 092 - Working Conditions Cause: Description Of Deficiency: Electrical Installations Shall Be Such That The Safety Of The Crew And Ship Shall Be Ensured. Psco Witnessed Numerous Wasted Electrical Boxes, Unsecured Electrical Wiring, And Improperly Installed Electrical Equipment On Deck In Cargo Area. 74 Solas (2020) Ii-1/40.1.3, Code 16 Due Date: 10/27/2023 12:00:00 Am Deficiency Resolved? Yes Resolved Date: 10/20/2023 12:00:00 Am Resolution Description: Received, Reviewed And Accepted Class Report / Proper Documentation From Bureau Veritas Stating The Deficienciency Was Rectified. System: 07 - Fire Safety Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: Manually Operated Call Points Shall Be Located Near Each Exit. Psco Saw Unmarked Call Point In Lower Er Level By Escape Hatch Forward Port. 74 Solas (2020) Ii-2/7.7, Code 16 Due Date: 10/27/2023 12:00:00 Am Deficiency Resolved? Yes Resolved Date: 10/20/2023 12:00:00 Am Resolution Description: Received, Reviewed And Accepted Class Report / Proper Documentation From Bureau Veritas Stating The Deficienciency Was Rectified. System: 15 - Safety Management Systems (ism) Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: The Company Should Maintain Procedures For Ships Conformity To Relevant Rules And Regulations. Due To The Objective Evidence In Above Deficiencies, A Safety Management External Audit Must Be Carried Out By The Administration Or R.o. Within 90 Days. 74 Solas (2020) Ix/3.2, Ism Code 6.4,7,10.1 Due Date: 10/13/2023 12:00:00 Am Deficiency Resolved? Yes Resolved Date: 10/20/2023 12:00:00 Am Resolution Description: Received, Reviewed And Accepted Class Report / Proper Documentation From Bureau Veritas Stating The Deficienciency Was Rectified. System: 03 - Water/weathertight Conditions Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: The Condition Of The Ship And Its Equipment Shall Be Maintained To Confirm With The Present Regulations. Psco Witnessed Hole In Sensor Stuffing Tube Near Ch #1 Portside. 74 Solas (2020) I/11 A, Code 16 Due Date: 10/27/2023 12:00:00 Am Deficiency Resolved? Yes Resolved Date: 10/20/2023 12:00:00 Am Resolution Description: Received, Reviewed And Accepted Class Report / Proper Documentation From Bureau Veritas Stating The Deficienciency Was Rectified. System: 06 - Cargo Operations Including Equipment Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: The Utilization Of Other Flammable Oils Employed Under Pressure In Power Transmission Systems Shall Be Such As To Ensure The Safety Of The Ship And Persons On Board. Psco Witnessed Ch #2 Had Temporary Soft Patch On Hydraulic Line On Deck, Causing Leaks Of Hydraulic Oil. 74 Solas (2020) Ii-2/4.2.4, Code 17, Ptd Due Date: N/a Deficiency Resolved? Yes Resolved Date: 10/20/2023 12:00:00 Am Resolution Description: Received, Reviewed And Accepted Class Report / Proper Documentation From Bureau Veritas Stating The Deficienciency Was Rectified.
Inspection date
2023-07-16
Technical ism manager
-
Inspection authority
VIETNAM
Address
-
Inspection port
Vung Ang
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
-
Deficiency description
-
Inspection date
2023-03-29
Technical ism manager
-
Inspection authority
TURKEY
Address
-
Inspection port
Gemlik
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
2
Deficiency description
Safety Of Navigation, 10116 - Nautical Publications, Missing Safety Of Navigation, 10109 - Lights, Shapes, Sound-signals, Inoperative
Inspection date
2022-11-10
Technical ism manager
-
Inspection authority
ITALY
Address
Uunit 1206 B, Cluster E, Saba 1 Tower, Jumeirah Lakes Towers, Dubai, United Arab Emirates
Inspection port
Ravenna
Phone
+971 4 368 7218
Inspection type
Detailed
Email
safety@densay.com
Detention
FALSE
Website
-
Ship deficiencies
12
Deficiency description
01307, Maximum Hours Of Work Or Minimum Hours Of Rest, Certificate & Documentation - Documents, 1011, Not As Required, 04108, Muster List, Emergency Systems, 1031, Incomplete, 18420, Cleanliness Of Engine Room, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 14615, Fuel Change-over Procedure, Pollution Prevention - Marpol Annex Vi, 1011, Not As Required, 13102, Auxiliary Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required, 14501, Garbage Shipboard Handling, Pollution Prevention - Marpol Annex V, 1011, Not As Required, 18417, Anchoring Devices, Labour Conditions - Health Protection, Medical Care, Social Security, 1086, Not Properly Maintained, 11117, Lifebuoys Incl. Provision And Disposition, Life Saving Appliances, 1011, Not As Required, 18407, Lighting (working Spaces), Labour Conditions - Health Protection, Medical Care, Social Security, 1082, Inoperative, 18302, Sanitary Facilities, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1086, Not Properly Maintained, 04102, Emergency Fire Pump And Its Pipes, Emergency Systems, 1011, Not As Required, 18321, Heating, Air Conditioning And Ventilation, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required,
Inspection date
2022-05-21
Technical ism manager
-
Inspection authority
PHILIPPINES
Address
-
Inspection port
Cebu
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
-
Deficiency description
-
Inspection date
2021-08-25
Technical ism manager
-
Inspection authority
UNITED KINGDOM
Address
Multergasse, St Gallen, Singapore
Inspection port
Gibraltar
Phone
-
Inspection type
Detailed
Email
-
Detention
FALSE
Website
-
Ship deficiencies
1
Deficiency description
04114, Emergency Source Of Power - Emergency Generator, Emergency Systems, 1011, Not As Required, , 0