Home>Vessels>SSI EXCELLENT
Vessel

SSI EXCELLENT

MARSHALL ISLANDS
MH flag

Country

MH flag
MARSHALL ISLANDS

Year

2016

Status

Active

Vessel details

Vessel MMSI number

538005986

Vessel IMO number

9693757

Vessel type

CARGO

Vessel subtype

BULK CARRIER

Gross tonnage

44003

Deadweight

81119

Twenty-foot Equivalent Unit (TEU)

Not Available

Vessel length in meters

229

Vessel breadth in meters

32.29

Ship liquid gas capacity

-

Call sign

V7IS5

Current vessel live info

Last position info time - - -

Current draught of the vessel

-

Maximum draught of the vessel

-

Current reported speed of the vessel

-

Current vessel speed in knots

-

Maximum speed of the vessel

-

Vessel activity status

-

Current vessel longitude

-

Current vessel latitude

-

Current vessel course in degrees

-

Current vessel heading in degrees

-

Port name of the next planned stop

-

Estimated time of arrival in UTC

-

Owner company details

Company name
Densay Shipping & Trading
Company type
OPERATOR / CONTROL
Country
UAE flagNot Available
Address
Unit 1206-a, Saba 1 Tower Cluster E, Jumeirah Lakes Towers, Dubai, United Arab Emirates
Parent company
Not Available
Parent company IMO
Not Available
Phone number
+971 4 368 7218
Email
operations@densaydubai.com
Website
http://www.densay.com/en/
LinkedIn
Not Available

Casualities details

Ship casualties, including types of incidents, specific dates, and additional narrative details.
Casualty date
2022-10-24
Casualty type
Other
Casualty details
Vessel disabled after blackout while approaching First Narrows in Vancouver, Canada. Crew restored power. Proceeded to anchor in Anchorage 10 for inspections.

Ship inspections

Inspection date
2023-10-11
Technical ism manager
Densay Shipping & Trading Dmcc
Inspection authority
UNITED STATES OF AMERICA
Address
-
Inspection port
New Orleans
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
4
Deficiency description
System: 07 - Fire Safety Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: The Condition Of The Ship And It’s Equipment Shall Be Maintained To Conform With The Provisions Of The Present Regulations To Ensure That The Ship In All Respects Will Remain Fit To Proceed To Sea Without Danger To The Ship Or Persons On Board. Psco Observed A Leak On Hydraulic Lines Located Above The Rope Storage Door On Top Of The A/c Vents. Vessel Had A Flange Wrapped In Cloth With A Collection Bucket Underneath. Due Date: N/a Deficiency Resolved? Yes Resolved Date: 10/12/2023 12:00:00 Am Resolution Description: Rcvd, Reviewed And Accepted Class Report Stating That The Crew Replaced The O-rings And System Was Tested Under Working Conditions To Satisfaction Of Class. System: 14 - Pollution Prevention Sub-system: 141 - Marpol Annex I Cause: Description Of Deficiency: The Condition Of The Ship And It’s Equipment Shall Be Maintained To Conform With The Provisions Of The Present Regulations To Ensure That The Ship In All Respects Will Remain Fit To Proceed To Sea Without Danger To The Ship Or Persons On Board. Psco Observed Inaccurate Soundings Of The Sludge Tank. Psco Could Not Verify The Soundings Of The Sludge Tank Against The Oil Record Book And Sounding Table. Due Date: 2/12/2024 12:00:00 Am Deficiency Resolved? No Resolved Date: N/a Resolution Description: N/a System: 13 - Propulsion And Auxiliary Machinery Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: The Machinery Associated Piping Systems And Fittings Shall Be Of A Design And Construction Adequate For The Service For Which They Are Intended And Shall Be So Installed And Protected As To Reduce To A Minimum Any Danger To Persons On Board, Due Regard Being Paid To Moving Parts, Hot Surfaces, And Other Hazards. Psco Observed Leaks On Generator #3 From The Cylinder #6 Resulting In Collection Of Fuel Oil In The Overflow Drainage Area. Upon Further Investigation, The #3 G/e Leak Drain Tank High Level Alarm Was Found Inoperable Caused By The Xp02 Control Processor Failure. Resulting In No Functional Alarms On All Three Generators. Due Date: N/a Deficiency Resolved? No Resolved Date: N/a Resolution Description: N/a System: 13 - Propulsion And Auxiliary Machinery Sub-system: N/a - No Subsystem Cause: Description Of Deficiency: The Purpose Of This Regulation Is To Prevent The Ignition Of The Combustible Materials Or Flammable Liquids. For This Purpose, The Following Functional Requirements Shall Be Met: Means Shall Be Provided To Control Leaks Of Flammable Liquids. Psco Observed Active Leaks On Incinerator Pump Fuel Lines. Due Date: N/a Deficiency Resolved? Yes Resolved Date: 10/12/2023 12:00:00 Am Resolution Description: Rcvd, Reviewed And Accepted Class Report Verifing That Leaks On The Fuel Oil Pumps Have Been Corrected.
Inspection date
2023-04-04
Technical ism manager
-
Inspection authority
POLAND
Address
27th Floor, South Island Place, 8, Wong Chuk Hang Road, Southern, Hong Kong, Turkey
Inspection port
Gdynia
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
3
Deficiency description
14101, Control Of Discharge, Pollution Prevention - Marpol Annex I, 1011, Not As Required, 11117, Lifebuoys Incl. Provision And Disposition, Life Saving Appliances, 100missing, 10109, Lights, Shapes, Sound-signals, Safety Of Navigation, 1082, Inoperative,
Inspection date
2022-12-12
Technical ism manager
-
Inspection authority
AUSTRALIA
Address
Unit 1206-a, Saba 1 Tower Cluster E, Jumeirah Lakes Towers, Dubai, United Arab Emirates
Inspection port
Fremantle
Phone
+971 4 368 7218
Inspection type
Initial
Email
operations@densaydubai.com
Detention
FALSE
Website
http://www.densay.com/en/
Ship deficiencies
6
Deficiency description
Electronic Charts (ecdis) ; Maintenance And Inspections ; Voyage Or Passage Plan ; Electrical; Lighting (working Spaces) Facilities For Reception Of Marine Safety Inform
Inspection date
2022-03-07
Technical ism manager
-
Inspection authority
NETHERLANDS
Address
Via Marchese Campodisola 13, 80133 , Naples, Turkey
Inspection port
Vlissingen
Phone
-
Inspection type
Detailed
Email
-
Detention
FALSE
Website
-
Ship deficiencies
3
Deficiency description
18408, Electrical, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 11119, Immersion Suits, Life Saving Appliances, 1011, Not As Required, 04103, Emergency, Lighting,batteries And Switches, Emergency Systems, 10