Home>Vessels>VIKING SEA
Vessel

VIKING SEA

NORWAY
NO flag

Country

NO flag
NORWAY

Year

2016

Status

Active

Vessel details

Vessel MMSI number

258215000

Vessel IMO number

9725421

Vessel type

PASSENGER

Vessel subtype

PASSENGER SHIP

Gross tonnage

47842

Deadweight

4870

Twenty-foot Equivalent Unit (TEU)

Not Available

Vessel length in meters

228.2

Vessel breadth in meters

28.8

Ship liquid gas capacity

-

Call sign

LAWP7

Current vessel live info

Last position info time - - -

Current draught of the vessel

-

Maximum draught of the vessel

-

Current reported speed of the vessel

-

Current vessel speed in knots

-

Maximum speed of the vessel

-

Vessel activity status

-

Current vessel longitude

-

Current vessel latitude

-

Current vessel course in degrees

-

Current vessel heading in degrees

-

Port name of the next planned stop

-

Estimated time of arrival in UTC

-

Owner company details

This vessel's owner company details are not available.

Casualities details

Ship casualties, including types of incidents, specific dates, and additional narrative details.
Casualty date
2022-09-17
Casualty type
Other
Casualty details
Vessel broke off her moorings at Ravenna Italy, in stormy, rainy weather with wind in gusts exceeding 100 km/hour. 5 tugs responded, it took them some 4 hours to take ship under control and keep her in stable position, avoiding grounding or collision. The ship was docked back at Cruise Terminal in the afternoon. No injuries or damages reported.

Ship inspections

Inspection date
2023-11-16
Technical ism manager
-
Inspection authority
UNITED STATES OF AMERICA
Address
-
Inspection port
San Juan, Puerto Rico
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
4
Deficiency description
System: 07 - Fire Safety sub-system: N/a - No Subsystem cause: Improper Installation description Of Deficiency: Fire Extinguishers Shall Be Situated Ready For Use At Easily Visible Places, Which Can Be Reached Quickly And Easily At Any Time In The Event Of A Fire, And In Such A Way That Their Serviceability Is Not Impaired By Weather, Vibration Or Other External Factors. Portable Fire Extinguishers Shall Be Provided With Devices Which Indicate Whether They Have Been Used. The Large Portable Fire Extinguisher Next To Purifier Room Was Not Secured. 74 Solas (20) Ii-2/10.3.2.4 10c due Date: 11/16/2023 12:00:00 Am deficiency Resolved? Yes resolved Date: 11/16/2023 12:00:00 Am resolution Description: N/a system: 07 - Fire Safety sub-system: N/a - No Subsystem cause: Improper/lack Of Maintenance description Of Deficiency: Fire Extinguishing Appliances Shall Be Readily Available. Excess Garbage In The Garbage Room Is Blocking Fire Fighting Appliances And Plans. 74 Solas (20) Ii-2/10.1.1.2 16ac due Date: 11/30/2023 12:00:00 Am deficiency Resolved? Yes resolved Date: 12/7/2023 12:00:00 Am resolution Description: Vessel Reported Excess Garbage Was Blocking Access To Fire Extinguisher In Centre Of The Space Which Has Since Been Cleared And All Fire Fighting Equipment Readily Accessible. Remote Survey Carried Out By Means Of The Document/photograph Review. system: 07 - Fire Safety sub-system: N/a - No Subsystem cause: description Of Deficiency: Ships Of All Types Shall Be Subdivided Into Spaces By Thermal And Structural Divisions Having Regard To The Fire Risks Of The Spaces. The Machinery Lift Stbd Side Deck 9 Space Had Installed Shelving With Combustible Material. 74 Solas (20) Ii-2/9.2.1 10c due Date: 11/16/2023 12:00:00 Am deficiency Resolved? Yes resolved Date: 11/16/2023 12:00:00 Am resolution Description: N/a system: 07 - Fire Safety sub-system: N/a - No Subsystem cause: Improper/lack Of Maintenance description Of Deficiency: Structural Fire Protection, Including Fire-resisting Divisions, And Protection Of Openings And Penetrations In These Divisions, Shall Be Kept In Good Order So As To Ensure Their Required Performance If A Fire Occurs. The Sliding Fire Screen Roller Door 7.4.04 Would Not Close When Released By Local Actuation. 74 Solas (20) Ii-2/14.2.1.1.1 16ac due Date: 11/30/2023 12:00:00 Am deficiency Resolved? Yes resolved Date: 12/7/2023 12:00:00 Am resolution Description: Vessel Reported Issue Was Due To The Adjustment Of The Shutter Magnet Which Has Now Been Adjusted And Rolling Fire Shutter 7.4.04 Now Fully Operational. Remote Survey Carried Out By Means Of Documents And Video Review And All Found Satisfactory.
Inspection date
2023-04-06
Technical ism manager
-
Inspection authority
CROATIA
Address
2, Central Avenue, Clydebank Business Park, Clydebank, Norway
Inspection port
Dubrovnik
Phone
-
Inspection type
Detailed
Email
-
Detention
FALSE
Website
-
Ship deficiencies
-
Deficiency description
-
Inspection date
2022-06-03
Technical ism manager
-
Inspection authority
CROATIA
Address
28th Oktovriou & Aimiliou Chourmouziou Street, Limassol, Norway
Inspection port
Dubrovnik
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
-
Deficiency description
-
Inspection date
2021-07-28
Technical ism manager
-
Inspection authority
CROATIA
Address
Friesenstrasse, Leer, Norway
Inspection port
Sibenik
Phone
-
Inspection type
Initial
Email
-
Detention
FALSE
Website
-
Ship deficiencies
-
Deficiency description
-

Viking Sea port map

© 2024 boatdb.
|